Execution standard:
GB/T 7551-1997 Certificate
(eqv OIML R60)
Combined error: 0.015%
Sealed to IEC 529:
Protection grade: IP67 or IP68.
Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water. |
|
Dimensions
(In mm. 1mm = 0.03937 inches)
CAP./SIZE
|
1t
|
2.2t
|
4.7t
|
10t
|
15t
|
22t
|
33t
|
47t
|
68t
|
100t
|
150t
|
220t
|
330t
|
470t
|
ΦA
|
49
|
49
|
49
|
74
|
75
|
75
|
95
|
130
|
130
|
150
|
150
|
225
|
225
|
270
|
ΦB
|
20
|
20
|
20
|
30
|
30
|
30
|
40
|
60
|
60
|
70
|
70
|
100
|
100
|
120
|
ΦC
|
60
|
60
|
60
|
75
|
75
|
75
|
95
|
130
|
130
|
150
|
150
|
225
|
225
|
270
|
H
|
43
|
43
|
43
|
50
|
50
|
50
|
65
|
75
|
85
|
90
|
100
|
130
|
145
|
170
|
J
|
-
|
-
|
-
|
7
|
7
|
7
|
7
|
7
|
7
|
7
|
7
|
10
|
10
|
10
|
K
|
7.5
|
7.5
|
7.5
|
6.5
|
6.5
|
6.5
|
10
|
14
|
14
|
16
|
16
|
24
|
24
|
28
|
R
|
15
|
15
|
15
|
25.4
|
25.4
|
25.4
|
50
|
60
|
-
|
-
|
-
|
-
|
-
|
-
|
Deep
|
2.2
|
2.2
|
2.2
|
3.3
|
3.3
|
3.3
|
3.3
|
5.1
|
-
|
-
|
-
|
-
|
-
|
-
|
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
<=15t: 5.0 m, 22~68t: 13m, >=100t: 5.0m
Diameter: Φ6
Connection:
Refer to the following drawing:
Notice: Do not change the length of cable, or lese, it will effect the sensitivity of loadcell.
Specification
Item Parameter
|
C3
|
Unit
|
Rated load (Emax):
|
1~470
|
t
|
Maximal numbers of load cell verification Intervals (Nlc):
|
3000
|
d
|
Minimum load cell verification intervals Intervals
( Vmin):
|
0.01
|
% of rated load
|
Rated output (Cn):
|
2.0±0.1%
|
mV/V
|
Combined error:
|
0.015
|
-% of rated output
|
Temperature effect on sensitivity(Tkc):
|
0.0012
|
=% of rated output/
|
Temperature effect on zero balance(Tk0):
|
0.0008
|
-% of rated output
|
Zero balance:
|
1.0
|
-% of rated output
|
Input resistance(Rlc):
|
775±5/>=33t:1550± 10
|
Ω(Ohms)
|
Output resistance(Ro):
|
702±2/>=33t:1402± 2
|
Ω(Ohms)
|
Insulation resistance:
|
≥5000
|
MΩ (Mega-Ohms)
|
Safe overload:
|
150
|
% of rated capability
|
Ultimate overload:
|
300
|
% of rated capability
|
Operating temperature range:
|
-20~+70/-20~+160
|
℃/ °F
|
Recommend excitation:
|
8~24
|
V( DC or AC)
|
Maximum excitation:
|
48
|
V( DC or AC)
|
Material of elastomer:
|
Alloy steel / Stainless steel
|
Protection class:
|