Vacuum valve -Gas valve
DYC-JQ series electro-magnetic pressure difference gas valve
DYC-JQ series electro-magnetic pressure difference gas valve is a special valve installed in the inlet of mechanical vacuum pump and open & close simultaneously.
When the pump stops working or power supply is suddenly interrupted, the valve will depend on atmospheric and vacuum pressure on making the valve plate closes automatically, will be closed vacuum system to maintain their vacuum, and the atmosphere through the throttle valve into the pump chamber in order to avoid pump oil return to vacuum system
The applicable active medium of this valve are air, non-corrosive gas
Characteristics Description:
Characteristics Description:
Main technical performance:
Scope(Pa) |
1051x10-3 |
Valve leak rate(Pa.L/S) |
1.0x10-4 |
Voltage(V/Hz) |
220/50 |
Medium temperature℃ |
-25+50 |
Time for opening and closing the valveS |
≤3 |
Installation |
Vertical or Horizontal |
Winding temperature℃ |
≤65 |
Outline and connection size
Model
|
DN
|
ΦD
|
ΦB
|
A/F
|
H
|
n/Φd
|
Connection
standard
|
DYC-JQ50
|
50
|
110
|
90
|
80/80
|
210
|
4-9
|
GB/T6070
|
DYC-JQ65
|
63
|
130
|
110
|
88/88
|
255
|
4-9
|
DYC-JQ80
|
80
|
145
|
125
|
98/98
|
285
|
8-9
|
DYC-JQ100
|
100
|
165
|
145
|
108/108
|
297
|
8-9
|
DYC-JQ125
|
125
|
200
|
175
|
138/138
|
300
|
8-11
|
DYC-JQ150
|
150
|
220
|
195
|
153/160
|
370
|
8-11
|
Jb919
|
DYC-JQ200
|
200
|
285
|
260
|
200/200
|
430
|
12-11
|
GB/T6070
|
|