| Execution standard: GB/T 7551-1997 Certificate (eqv OIML R60) Combined error: 0.015% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water. |
|
Dimensions
(In mm. 1mm = 0.03937 inches)
![]() |
![]() |
Circuit Diagram:
6 Core cable connection:

Notice:The 7 and/or 5 wires of cable should be short circuit before using.
Specification
|
Item Parameter |
C3 |
Unit |
|
Rated load (Emax): |
10,20,30,40,50 |
t |
|
Maximal numbers of load cell verification Intervals (Nlc): |
3000 |
d |
|
Minimum load cell verification intervals Intervals ( Vmin): |
0.01 |
% of rated load |
|
Rated output (Cn): |
30,000 or 100,000 |
d |
|
Combined error: |
0.015 |
-% of rated output |
|
Temperature effect on sensitivity(Tkc): |
0.0012 |
=% of rated output/ |
|
Temperature effect on zero balance(Tk0): |
0.0008 |
-% of rated output |
|
Zero balance: |
1.0 |
-% of rated output |
|
Measuring rate A/D: |
50/25 |
/Sec |
|
Baudrate: |
9600/19200 |
Bps |
|
Filter mode 1: |
3~0.05(Low pass filter) |
HZ |
|
Filter mode 0: |
8~3(Low pass filter) |
HZ |
|
Maxium transmission distance: |
1200 |
m |
|
Safe overload: |
150 |
% of rated capability |
|
Ultimate overload: |
300 |
% of rated capability |
|
Operating temperature range: |
-20~+70/-20~+160 |
℃/ °F |
|
Recommend excitation: |
8~15 |
V( DC or AC) |
|
Maximum excitation: |
24 |
V( DC or AC) |
|
Material of elastomer: |
Alloy steel / Stainless steel |
|
|
Protection class: |
IP67/IP68 |
|
Hotline.
Ms. Vân Anh - 0904883101